- move IRQ control to main code (only the main code knows exactly which combination of pins is used for com2) - split one big module into multiple smaller files (easier to maintain)
82 lines
2.3 KiB
NASM
82 lines
2.3 KiB
NASM
; ***************************************************************************
|
|
; copyright : (C) 2026 by Martin Preuss
|
|
; email : martin@libchipcard.de
|
|
;
|
|
; ***************************************************************************
|
|
; * This file is part of the project "AqHome". *
|
|
; * Please see toplevel file COPYING of that project for license details. *
|
|
; ***************************************************************************
|
|
|
|
#ifndef AVR_MODULES_COM2W2_BYTEREAD_H
|
|
#define AVR_MODULES_COM2W2_BYTEREAD_H
|
|
|
|
|
|
.cseg
|
|
|
|
|
|
|
|
; ---------------------------------------------------------------------------
|
|
; @routine com2w2RecvByteWaitForQuietClk
|
|
;
|
|
; Wait until the clock line is consistently high for 1ms.
|
|
;
|
|
; @clobbers r18, r20, r22
|
|
|
|
com2w2RecvByteWaitForQuietClk:
|
|
ldi r18, 200
|
|
com2w2RecvByteWaitForQuietClk_loop:
|
|
ldi r20, 100 ; wait up to 1ms for clock high (R20, R22)
|
|
rcall com2w2WaitForClockLowMulti10Us ; (r20, r22)
|
|
brcs com2w2RecvByteWaitForQuietClk_waitForLow
|
|
dec r18
|
|
brne com2w2RecvByteWaitForQuietClk_loop
|
|
rjmp com2w2RecvByteWaitForQuietClk_ret
|
|
com2w2RecvByteWaitForQuietClk_waitForLow:
|
|
ldi r20, 100 ; wait up to 1ms for clock low (R20, R22)
|
|
rcall com2w2WaitForClockLowMulti10Us
|
|
brcc com2w2RecvByteWaitForQuietClk_ret ; not low within 1ms, assume line is quiet
|
|
brne com2w2RecvByteWaitForQuietClk_loop
|
|
com2w2RecvByteWaitForQuietClk_ret:
|
|
ret
|
|
|
|
|
|
|
|
; ---------------------------------------------------------------------------
|
|
; @routine com2w2RecvByte
|
|
;
|
|
; @return CFLAG set if byte received, cleared on error
|
|
; @return r16 byte received
|
|
; @clobbers r17, r18, r20, r22
|
|
|
|
com2w2RecvByte:
|
|
ldi r17, 8
|
|
clr r16
|
|
com2w2RecvByte_loop:
|
|
ldi r20, 100 ; wait up to 1ms for clock low
|
|
rcall com2w2WaitForClockLowMulti10Us ; (R20, R22)
|
|
brcc com2w2RecvByte_end
|
|
ldi r20, 100 ; wait up to 1ms for clock high
|
|
rcall com2w2WaitForClockHighMulti10Us ; (R20, R22)
|
|
brcc com2w2RecvByte_end
|
|
; handle received bit
|
|
inr r18, COM_DATA_INPUT
|
|
andi r18, (1<<COM_DATA_PIN)
|
|
clc
|
|
breq com2w2RecvByte_clockData
|
|
sec
|
|
com2w2RecvByte_clockData:
|
|
ror r16
|
|
dec r17
|
|
brne com2w2RecvByte_loop
|
|
sec
|
|
com2w2RecvByte_end:
|
|
ret
|
|
; @end
|
|
|
|
|
|
|
|
|
|