Files
aqhomecontrol/avr/apps/fan_control/recv.asm
Martin Preuss 88a66f6822 avr: add complex fan controller app with base classes to be used by other apps as well.
- add modules
  - holdtimer (keep actor running while triggered)
  - triggeraction (connect actor with holdtimer)
- add app fan_controller
  - uses the modules mentioned above to turn on/off fans in connection
    with e.g. motion sensor nodes
2026-08-06 00:05:50 +02:00

78 lines
2.6 KiB
NASM

; ***************************************************************************
; copyright : (C) 2026 by Martin Preuss
; email : martin@libchipcard.de
;
; ***************************************************************************
; * This file is part of the project "AqHome". *
; * Please see toplevel file COPYING of that project for license details. *
; ***************************************************************************
#ifndef AQH_AVR_APPS_FAN_CONTROL_RECV_ASM
#define AQH_AVR_APPS_FAN_CONTROL_RECV_ASM
.cseg
; ---------------------------------------------------------------------------
; @routine AppMotionLight_OnPacketReceived @global
;
; @clobbers any, -X
AppFanControl_OnPacketReceived:
ldi zl, LOW(appFanControlObjectFlash*2)
ldi zh, HIGH(appFanControlObjectFlash*2)
push zl
push zh
lpm yl, Z+
lpm yh, Z
ldi zl, LOW(appFanControlMsgTable*2)
ldi zh, HIGH(appFanControlMsgTable*2)
bigcall Main_HandleValueMsg
pop zh
pop zl
AppFanControl_OnPacketReceived_ret:
ret
; @end
; ---------------------------------------------------------------------------
; @routine appFanControlSetValue
;
; @clobbers any, -X
appFanControlSetValue:
std Y+APP_FANCONTROL_RAM_OFFS_VALUE_LO, r18
std Y+APP_FANCONTROL_RAM_OFFS_VALUE_HI, r19
bigjmp TCA_SetValueACK
; @end
appFanControlMsgTable:
.db NETMSG_CMD_VALUE_REPORT, 0, LOW(TCA_HandleMsg), HIGH(TCA_HandleMsg)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_GUARDSRC, LOW(TCA_SetValue_GuardSrc), HIGH(TCA_SetValue_GuardSrc)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_GUARDLIM, LOW(TCA_SetValue_GuardLimits), HIGH(TCA_SetValue_GuardLimits)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_TRIGGER1SRC, LOW(TCA_SetValue_Trigger1Src), HIGH(TCA_SetValue_Trigger1Src)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_TRIGGER1LIM, LOW(TCA_SetValue_Trigger1Limits), HIGH(TCA_SetValue_Trigger1Limits)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_TRIGGER2SRC, LOW(TCA_SetValue_Trigger2Src), HIGH(TCA_SetValue_Trigger2Src)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_TRIGGER2LIM, LOW(TCA_SetValue_Trigger2Limits), HIGH(TCA_SetValue_Trigger2Limits)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_HOLDTIME, LOW(TCA_SetValue_HoldTime), HIGH(TCA_SetValue_HoldTime)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_MODE, LOW(TCA_SetValue_Mode), HIGH(TCA_SetValue_Mode)
.db NETMSG_CMD_VALUE_SET, VALUE_ID_FANCTRL_VALUE, LOW(appFanControlSetValue), HIGH(appFanControlSetValue)
.db 0, 0, 0, 0
#endif