moved device files back into separate folder

otherwise installed module files are not update when compiling without AVR.
This commit is contained in:
Martin Preuss
2025-10-25 16:38:44 +02:00
parent 617c8551dc
commit ced89d9845
31 changed files with 15 additions and 64 deletions

View File

@@ -2,15 +2,30 @@
<gwbuild>
<data dist="true" install="$(datadir)/aqhome/devices/nodes">
aqua_c01.xml
aqua_c02.xml
aqua_n06.xml
aqua_n11.xml
aqua_n12.xml
aqua_n14.xml
aqua_n15.xml
aqua_n16.xml
aqua_n17.xml
aqua_n18.xml
aqua_n19.xml
aqua_n20.xml
aqua_n21.xml
aqua_n22.xml
aqua_n24.xml
aqua_n25.xml
aqua_n26.xml
aqua_n27.xml
aqua_n28.xml
aqua_r05.xml
aqua_r06.xml
aqua_s03.xml
aqua_t03.xml
aqua_t04.xml
</data>
</gwbuild>

View File

@@ -0,0 +1,12 @@
<device name="aqua_c01" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>C</devicetype>
<deviceversion>1</deviceversion>
<values>
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,12 @@
<device name="aqua_c02" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>C</devicetype>
<deviceversion>2</deviceversion>
<values>
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,25 @@
<device name="aqua_n14" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>N</devicetype>
<deviceversion>14</deviceversion>
<values>
<value name="DS18B20_TEMP" id="0x06" type="sensor" dataType="rational" modality="temperature" units="C" denom="16" />
<value name="RGBWSTATE" id="0x81" type="actor" dataType="uint16" modality="onOff"/>
<value name="NUMLEDS" id="0x82" type="actor" dataType="int" />
<value name="RGBWVALUE" id="0x83" type="actor" dataType="dword" modality="rgbw"/>
<value name="RGBWMODE" id="0x8b" type="actor" dataType="int" modality="onOffAuto" />
<value name="MALONTIME" id="0x85" type="actor" dataType="uint16" />
<value name="MALSOURCE1" id="0x86" type="actor" dataType="uint16" />
<value name="MALSOURCE2" id="0x87" type="actor" dataType="uint16" />
<value name="MALSOURCEB" id="0x89" type="actor" dataType="uint16" />
<value name="MALVALUEB" id="0x8a" type="actor" dataType="uint16" />
<value name="MALSTATE" id="0x07" type="sensor" dataType="uint16" modality="onOff" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,17 @@
<device name="aqua_n16" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>N</devicetype>
<deviceversion>16</deviceversion>
<values>
<value name="SI7021_TEMP" id="0x01" type="sensor" dataType="rational" modality="temperature" units="C" denom="100" />
<value name="SI7021_HUM" id="0x02" type="sensor" dataType="rational" modality="humidity" units="%" denom="1" />
<value name="MOTION" id="0x07" type="sensor" dataType="rational" modality="motion" denom="1" />
<value name="DOOR" id="0x08" type="sensor" dataType="rational" modality="door" denom="1" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,17 @@
<device name="aqua_n21" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>N</devicetype>
<deviceversion>21</deviceversion>
<values>
<value name="SI7021_TEMP" id="0x01" type="sensor" dataType="rational" modality="temperature" units="C" denom="100" />
<value name="SI7021_HUM" id="0x02" type="sensor" dataType="rational" modality="humidity" units="%" denom="1" />
<value name="ADC" id="0x03" type="sensor" dataType="uint16" denom="1" />
<value name="MOTION" id="0x07" type="sensor" dataType="rational" modality="motion" denom="1" />
<value name="DOOR" id="0x08" type="sensor" dataType="rational" modality="door" denom="1" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,19 @@
<device name="aqua_n24" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>N</devicetype>
<deviceversion>24</deviceversion>
<values>
<value name="SI7021_TEMP" id="0x01" type="sensor" dataType="rational" modality="temperature" units="C" denom="100" />
<value name="SI7021_HUM" id="0x02" type="sensor" dataType="rational" modality="humidity" units="%" denom="1" />
<value name="MOTION" id="0x07" type="sensor" dataType="rational" modality="motion" denom="1" />
<value name="SGP40_VALUE" id="0x08" type="sensor" dataType="rational" modality="tvoc" denom="1" />
<value name="SGP30_TVOC" id="0x09" type="sensor" dataType="rational" modality="tvoc" denom="1" />
<value name="SGP30_CO2" id="0x0a" type="sensor" dataType="rational" modality="co2" denom="1" />
<value name="LIGHT" id="0x0b" type="sensor" dataType="rational" modality="light" denom="1" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,25 @@
<device name="aqua_n25" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>N</devicetype>
<deviceversion>25</deviceversion>
<values>
<value name="DS18B20_TEMP" id="0x06" type="sensor" dataType="rational" modality="temperature" units="C" denom="16" />
<value name="RGBWSTATE" id="0x81" type="actor" dataType="uint16" modality="onOff" />
<value name="NUMLEDS" id="0x82" type="actor" dataType="int" />
<value name="RGBWVALUE" id="0x83" type="actor" dataType="dword" modality="rgbw"/>
<value name="RGBWMODE" id="0x8b" type="actor" dataType="int" modality="onOffAuto" />
<value name="MALONTIME" id="0x85" type="actor" dataType="uint16" />
<value name="MALSOURCE1" id="0x86" type="actor" dataType="uint16" />
<value name="MALSOURCE2" id="0x87" type="actor" dataType="uint16" />
<value name="MALSOURCEB" id="0x89" type="actor" dataType="uint16" />
<value name="MALVALUEB" id="0x8a" type="actor" dataType="uint16" />
<value name="MALSTATE" id="0x07" type="sensor" dataType="uint16" modality="onOff" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,14 @@
<device name="aqua_n26" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>N</devicetype>
<deviceversion>26</deviceversion>
<values>
<value name="SGP30_TVOC" id="0x09" type="sensor" dataType="rational" modality="tvoc" denom="1" />
<value name="SGP30_CO2" id="0x0a" type="sensor" dataType="rational" modality="co2" denom="1" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,16 @@
<device name="aqua_n27" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>N</devicetype>
<deviceversion>27</deviceversion>
<values>
<value name="SI7021_TEMP" id="0x01" type="sensor" dataType="rational" modality="temperature" units="C" denom="100" />
<value name="SI7021_HUM" id="0x02" type="sensor" dataType="rational" modality="humidity" units="%" denom="1" />
<value name="MOTION" id="0x07" type="sensor" dataType="rational" modality="motion" denom="1" />
<value name="LIGHT" id="0x0b" type="sensor" dataType="rational" modality="light" denom="1" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,16 @@
<device name="aqua_n28" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>N</devicetype>
<deviceversion>28</deviceversion>
<values>
<value name="SI7021_TEMP" id="0x01" type="sensor" dataType="rational" modality="temperature" units="C" denom="100" />
<value name="SI7021_HUM" id="0x02" type="sensor" dataType="rational" modality="humidity" units="%" denom="1" />
<value name="ADC" id="0x03" type="sensor" dataType="uint16" denom="1" />
<value name="DOOR" id="0x08" type="sensor" dataType="rational" modality="door" denom="1" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,14 @@
<device name="aqua_r05" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>R</devicetype>
<deviceversion>5</deviceversion>
<values>
<value name="DS18B20_TEMP" id="0x06" type="sensor" dataType="rational" modality="temperature" units="C" denom="16" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
<value name="addressRange" id="0x89" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,11 @@
<device name="aqua_r06" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>R</devicetype>
<deviceversion>6</deviceversion>
<values>
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,12 @@
<device name="aqua_s03" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>S</devicetype>
<deviceversion>3</deviceversion>
<values>
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,13 @@
<device name="aqua_t03" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>T</devicetype>
<deviceversion>3</deviceversion>
<values>
<value name="DS18B20_TEMP" id="0x06" type="sensor" dataType="rational" modality="temperature" units="C" denom="16" />
<value name="LEDTIMING" id="0x88" type="actor" dataType="uint16" />
</values>
</device>

View File

@@ -0,0 +1,11 @@
<device name="aqua_t04" driver="nodes">
<manufacturer>AQUA</manufacturer>
<devicetype>T</devicetype>
<deviceversion>4</deviceversion>
<values>
<value name="DS18B20_TEMP" id="0x06" type="sensor" dataType="rational" modality="temperature" units="C" denom="16" />
</values>
</device>