updated readme.
This commit is contained in:
@@ -12,23 +12,15 @@ turned off again.
|
|||||||
Typical usage is to watch for a motion message from some node with a motion sensor and react to that.
|
Typical usage is to watch for a motion message from some node with a motion sensor and react to that.
|
||||||
This app can watch for up to two node-value pairs.
|
This app can watch for up to two node-value pairs.
|
||||||
|
|
||||||
|
This app can also watch for brightness sensor messages to only turn on light if it is dark enough.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
1. Values
|
1. Values
|
||||||
======
|
======
|
||||||
|
|
||||||
1.1 MALRGBWVALUE
|
|
||||||
----------------
|
|
||||||
|
|
||||||
RGB Value for activated light:
|
1.1 MALONTIME
|
||||||
aqhome-tool setdata -N nodes/XXXXXXXX/MALRGBWVALUE -v GRWB
|
|
||||||
|
|
||||||
Example:
|
|
||||||
Set color of LED strip to blue (half intensity)
|
|
||||||
aqhome-tool setdata -N nodes/12345678/MALRGBWVALUE -v 0x80
|
|
||||||
|
|
||||||
|
|
||||||
1.2 MALONTIME
|
|
||||||
-------------
|
-------------
|
||||||
On-Time after activation:
|
On-Time after activation:
|
||||||
aqhome-tool setdata -N nodes/XXXXXXXX/MALONTIME TIME_IN_1/10_SECS
|
aqhome-tool setdata -N nodes/XXXXXXXX/MALONTIME TIME_IN_1/10_SECS
|
||||||
@@ -38,7 +30,7 @@ Example:
|
|||||||
aqhome-tool setdata -N nodes/12345678/MALONTIME -v 200
|
aqhome-tool setdata -N nodes/12345678/MALONTIME -v 200
|
||||||
|
|
||||||
|
|
||||||
1.3. MALSOURCE1, MALSOURCE2
|
1.2. MALSOURCE1, MALSOURCE2
|
||||||
---------------------------
|
---------------------------
|
||||||
|
|
||||||
Sources for Motion Messages:
|
Sources for Motion Messages:
|
||||||
@@ -53,4 +45,36 @@ Example:
|
|||||||
aqhome-tool setdata -N nodes/12345678/MALSOURCE1 -v 0x0702
|
aqhome-tool setdata -N nodes/12345678/MALSOURCE1 -v 0x0702
|
||||||
|
|
||||||
|
|
||||||
|
1.3. MALSOURCEB
|
||||||
|
---------------------------
|
||||||
|
|
||||||
|
Source for Birightness Messages:
|
||||||
|
aqhome-tool setdata -N nodes/XXXXXXXX/MALSOURCEB -v VVNN
|
||||||
|
|
||||||
|
VVNN is a 16-bit value, lower 8 bit contain the source node address, higher 8 bit contain the
|
||||||
|
value id to react to.
|
||||||
|
|
||||||
|
If no brightness source is given (i.e. NN part is 0) then brightness will be ignored.
|
||||||
|
|
||||||
|
Example:
|
||||||
|
React to value report messages with value id 0b (LIGHT) from node with address 2
|
||||||
|
aqhome-tool setdata -N nodes/12345678/MALSOURCEB -v 0x0b02
|
||||||
|
|
||||||
|
|
||||||
|
1.4. MALVALUEB
|
||||||
|
---------------------------
|
||||||
|
|
||||||
|
Brightness value below which light is to be turned on.
|
||||||
|
aqhome-tool setdata -N nodes/XXXXXXXX/MALVALUEB -v NN
|
||||||
|
|
||||||
|
The value highly depends on the type of sensor. Those photodiodes used e.g. by N27 nodes
|
||||||
|
have values between 0-1023 but the actual range depends on many factors (like location of the
|
||||||
|
sensor etc).
|
||||||
|
|
||||||
|
Therefore this value can be adjusted here.
|
||||||
|
|
||||||
|
Example:
|
||||||
|
Only turn light on if brightness sensor reports a value below 200
|
||||||
|
aqhome-tool setdata -N nodes/12345678/MALVALUEB -v 200
|
||||||
|
|
||||||
|
|
||||||
|
|||||||