This is the inter-node communication protocol.

Hardware
========

AqHome uses synchronous serial communication, nodes are connected via 4 lines:
- 5V
- GND
- DATA (0V/3.3V)
- ATTN (0V/3.3V)

DATA and ATTN are only pulled low by nodes on the bus, pulled high only by a single node in the network via pull-up
resistor. This allows for multi-master mode. Every node sends data at will (after checking for free line).
In most cases the pull-up resistors are installed on the node with the 5V power supply.


5V, GND
-------
Power line 5V, mcu nodes use a voltage regulator to locally provide stable 3.3V.


DATA
----
Data line, normally high, bits are sampled on the rising edge.


CLK
----
Clock line, normally high. Pulled down at the beginning of a transmission, held low for a short time to let
other nodes on the network discover this state. After that data is clocked out on the DATA line at the rising edge
of the CLK line.



Protocol
========

The protocol is simple to reduce overhead and to keep the code size inside the mcu nodes small.
There is no generic request-reply protocol. Messages are not repeated on the lowlevel layer. However,
if a message can't be transmitted because of a busy line it might get retried later by the sending node (e.g. when
reporting sensor data). Also, some operations consist of a request and a reply, but that's on a higher level (e.g.
remotely setting a specific value in a node). The maximum size of a message is 24 bytes (max. 21 bytes payload).


Basic Message Format
--------------------

Nodes communicate via messages. The first byte of every message is the destination node address, so every node can determine
after the first byte whether it is interested in the following message. The last byte is a CRC8 checksum byte although this
is for historical reasons not a real CRC8 checksum (due to an implementation error in early versions).

Offset Length Meaning
---------------------------------------------------------------
     0      1 destination address
     1      1 remaining message length (excluding the CRC byte)
---------------------------------------------------------------
     2      n payload data
---------------------------------------------------------------
     2+n    1 CRC byte


Command Messages
----------------

Command messages are an extension to the Basic Message Format specifying the first two bytes of the payload.
The first byte of the payload is a command code (e.g. "100" for report of sensor data), followed by the
bus address of the sender. The remainder of the payload is defined by the type of message(i.e. the message code).


Offset Length Meaning
----------------------------------------------------------------
     0      1 destination address
     1      1 remaining message length
----------------------------------------------------------------
     2      1 command code
     3      1 source address
----------------------------------------------------------------
     4      n remaining payload data (depending on command code)
----------------------------------------------------------------
     4+n    1 CRC byte